Bram van Ginneken
University Medical Center Utrecht · 2 papers here · 4 ideas from their work
View on OpenAlex ORCID 0000-0003-2028-8972
Ideas from their papers
- ContourDrift: continuous QA monitor for deployed auto-segmentation
A workflow add-on that scores every AI-generated contour against the clinician's final approved contour and aggregates the results into live dashboards, alerting radiotherapy physics teams when auto-contour quality drifts after a scanner, protocol, or patient-population change. Alongside overlap and boundary-distance metrics, it tracks how much of each AI contour clinicians leave unedited and calibrates alert thresholds to the clinic's own observer variability, so it can catch both model drift and early signs of automation bias. Monthly exports double as post-market surveillance documentation for regulators and vendors.
- GoLive Contour Scorecard: pre-deployment validation for auto-segmentation AI
An independent validation service that runs a hospital's auto-contouring model against held-out, expert-annotated CT/MRI case batteries and returns a standardized per-structure scorecard that pairs geometric metrics with clinician accept/reject review. It gives physics and clinical leads the go/no-go evidence they need before the tool touches patients, and explicitly flags structures where metric scores and clinical usefulness diverge.
- CaudateScore: trial-ready caudate volumetry with per-case QC
An imaging-biomarker service for Huntington's disease trials that automatically measures caudate nucleus volume from routine brain MRI and attaches a standardized per-case quality score to every measurement, so sponsors can audit which scans need manual re-reads. The workflow is deliberately hybrid — low-scoring cases go to trained raters — because challenge benchmarks show automated segmentation still trails interactive expert quality. Quality scores are calibrated against human expert variability and stratified by site and scanner, giving regulators a documented audit trail instead of a black box.
- TurnTaker: an expertise-calibrated human-AI correction console for cephalometric tracings
TurnTaker is a correction-session console, not a landmark detector: it sits on top of any existing auto-landmarker and decides, for each landmark, whether the AI states its placement and moves on or explicitly hands the floor to the clinician, with the policy tuned to whether the operator is a trainee or an experienced orthodontist. A narrative review of AI in orthodontics now corroborates the premise — CNN landmarking meets the 2-mm clinical threshold and reduces inter-examiner variability, yet clinician oversight remains a stated requirement — which shifts the design problem from detection accuracy to how oversight is organized. Because performance generalizes unevenly across imaging systems, the console treats confidence as device-relative and recalibrates its handoff thresholds per site, with mixed-expertise teaching clinics as the first wedge.