AI-generated Drafted 2026-11-16 by GLM and Gemma 4. Numbers are ranges; move them to explore. Plan still being written.
ContourDrift makes money through annual per-department subscriptions sold to radiotherapy physics teams for a continuous auto-contour QA dashboard, with an upsell of anonymised fleet-telemetry and post-market-surveillance reports to auto-contouring vendors. The one thing that must be true: the raw pre-edit AI contour can be captured — via vendor APIs or the clinic's own DICOM-RT/PACS layer — so the metric stream flows without an OEM veto.
Subscription modelCustomer = one radiotherapy department (cancer centre) in United Kingdom (NHS and private radiotherapy centres) as beachhead, then Western Europe and US Technology readiness TRL 4 /9 Location matters somewhat
Assumed84 Researched0 Validated0 Invalidated0 Key Partners12 Microsoft Azure VM compute, blob storage, managed containers, UK South/UK West + EU regions · Candidate for Production SaaS hosting (UK/EU regions, DTAC-aligned) · public pay-as-you-go price lists & pricing calculator dcm4che open-source community Provides Open-source DICOM toolkit support & maintenance. Open-source DICOM/DICOM-RT toolkit and archive underpinning the contour capture and parsing pipeline. ESTRO Congress, workshops, journal (Radiotherapy & Oncology) channels · Candidate for ESTRO congress, workshop & journal presence · Congress registration fees and exhibition/sponsorship rates are published annually IPEM Membership, conferences, QA guidance · Candidate for IPEM membership, conference & guidance alignment · Membership rates published on ipem.ac.uk Varian / Siemens Healthineers ARIA/Eclipse integration points · Candidate for ARIA/PACS-side pre-edit contour capture integration · Integration/API program terms not public Mirada Medical DLCExpert; API access · Candidate for DLCExpert API access & joint integration · API terms not public Limbus AI Limbus Contour; API access · Candidate for Limbus Contour API access & integration · API terms not public dcm4che community Open-source DICOM toolkit, DICOM-RT parsing, PACS tooling · Candidate for Open-source DICOM toolkit support & maintenance · Free (open source) Mirada Medical Provides DLCExpert API access & joint integration. Oxford-based radiotherapy software vendor whose DLCExpert/Box auto-contouring is deployed in UK clinics; API partner for pre-edit contour capture and a potential telemetry subscriber. Limbus AI Provides Limbus Contour API access & integration. AI auto-contouring vendor (Limbus Contour) with strong UK/NZ presence; API access partner and telemetry customer. Varian, a Siemens Healthineers company Provides ARIA/PACS-side pre-edit contour capture integration. Dominant installed base via ARIA PACS/Eclipse TPS and Ethos adaptive contouring; integration partner for PACS-side capture, though its built-in Ethos QA is a partial substitute and a competitive risk. IPEM (Institute of Physics and Engineering in Medicine) Provides IPEM membership, conference & guidance alignment. UK professional body for medical physics; peer-review publication and guidance alignment route to physics-team trust in the beachhead market. Key Activities10 Core metric & control-chart engine Implement per-case Dice, mean distance to agreement, Hausdorff distance and unedited-slice fraction computation on DICOM-RT structure pairs; weekly per-structure statistical control charts with variability-calibrated limits and drift alert logic. Pre-edit contour capture & integration layer Build DICOM-RT/PACS sidecar capture of raw pre-edit AI contours plus vendor API adapters (Mirada, Limbus, Varian ARIA/Ethos) — the critical dependency: no telemetry stream without it. Regulatory classification, QMS & NHS compliance pack Determine MDR/UKCA device classification; stand up ISO 13485/IEC 62304 software lifecycle; DCB0129/0160 clinical risk management and DTAC evidence pack for NHS procurement. Observer-variability calibration methodology Multi-observer study protocol and tooling to quantify local inter-/intra-observer variability per structure and set control limits plus automation-bias sentinel thresholds. Reference-trust pilot & validation publication Live pilot at a reference NHS trust running weekly control charts on real auto-contouring cases; peer-reviewed publication and case study to unlock first sales. SaaS hosting & dashboard operations Azure UK/EU-hosted ingestion pipeline, dashboards, alerting and monthly exports with data residency and clinical-safety incident management. Customer success & physics support Onboarding calibration studies, alert triage support, annual recalibration and quarterly physics review meetings per department. Vendor telemetry & PMS report production Anonymised fleet aggregation, consent management and monthly post-market surveillance exports per vendor subscriber. Sales & physics-community presence Direct sales to physics leads, IPEM/ESTRO/AAPM conference and publication presence, and DTAC-ready procurement packs. Independent contour review audits Periodic random-sample independent review of accepted-unmodified contours to counter automation bias, scheduled per department. Key Resources7 Drift-detection & calibration algorithm suite Proprietary control-chart logic calibrated to observer variability, automation-bias sentinel and multi-signal disagreement flagging — the defensible core. Medical-physics + DICOM-RT engineering team Scarce combination of radiotherapy physics domain expertise and DICOM-RT/PACS integration engineering, strongly clustered in the UK. Anonymised contour-pair & fleet telemetry archive Growing archive of paired AI-vs-approved contours across clinics, scanners and protocols — the moat that improves calibration and vendor telemetry value over time. Reference NHS trust design partnership Design and evidence partnership with a leading trust (e.g., The Royal Marsden) providing workflow access and co-authored validation. Vendor API access agreements Contracts with auto-contouring vendors (Mirada, Limbus, Varian) for pre-edit contour access — the single dependency the business depends on. Seed capital Approximately £1.5-2.5m to fund 18-24 months of build, pilot and first NHS subscriptions. UK hub near the London-Oxford radiotherapy cluster Small hub for proximity to reference clinics, vendors (Mirada in Oxford) and scarce physics talent. Value Propositions3 ContourDrift Core QA Dashboard Turns routine clinical edits into an always-on validation stream that catches model drift after scanner, protocol or population changes before patients are affected — and produces regulator-ready documentation at no extra effort. Observer-Variability Calibration Onboarding Alerts fire only on drift beyond human noise, not on normal editing differences — the credibility foundation physics teams demand before trusting any monitor. Fleet Telemetry & Post-Market Surveillance Reports Production-grounded, fleet-wide evidence of real-world auto-contour performance that vendors cannot gather themselves and regulators increasingly expect. Customer Relationships4 NHS radiotherapy physics teams Win via design-partner pilots with reference trusts, IPEM peer-reviewed evidence and a pre-packaged DTAC/DCB0129 compliance pack; keep through quarterly physics reviews, annual recalibration to local observer variability and co-authored publications. Private & European multi-site radiotherapy centres Win through fleet-level dashboards, cross-site benchmarking and multi-site subscription pricing; keep with multi-year contracts and shared quarterly fleet performance reviews. US academic cancer centres Win via peer-reviewed methodology and AAPM-community presence; keep through research collaborations, shared datasets and multi-campus licences. Auto-contouring vendors Win through API partnerships and unique clinic-side telemetry they cannot gather themselves; keep via monthly PMS-ready exports and co-marketing as a monitored/trusted deployment badge. Channels1 ESTRO (European Society for Radiotherapy and Oncology) European professional society whose congress, workshops and journal provide the visibility channel to Western European physics teams. Customer Segments4 NHS radiotherapy physics teams Auto-contour quality degrades silently after scanner, protocol or patient-population changes; teams have no continuous post-deployment QA layer, no automation-bias sentinel, and no audit-grade documentation for vendor accountability or regulatory oversight. · 1 named organization Private & European multi-site radiotherapy centres Fleet-wide visibility of auto-contour performance across sites, scanners and protocols is manual and inconsistent; no aggregated drift telemetry, benchmarking or cross-site QA standard exists. US academic cancer centres Same post-deployment QA gap, compounded by FDA-aligned post-market surveillance expectations for AI tools used in clinical care and multi-campus scanner heterogeneity. · 1 named organization Auto-contouring vendors Vendors are blind to how their tools perform in production across clinics and carry MDR/FDA post-market surveillance obligations they cannot document from real-world use. Cost Structure€789k in year 3 + €837k one-off Production SaaS hosting (UK/EU regions, DTAC-aligned) €23k To Microsoft Azure · per active customer Dev, pilot & telemetry archive environment €8.4k To Microsoft Azure · fixed monthly ESTRO congress, workshop & journal presence €9.6k To ESTRO (European Society for Radiotherapy and Oncology) · fixed monthly Targeted demos & workshops per new customer (CAC) €57k To ESTRO (European Society for Radiotherapy and Oncology) · per new customer IPEM membership, conference & guidance alignment €3.0k To IPEM (Institute of Physics and Engineering in Medicine) · fixed monthly ARIA/PACS-side pre-edit contour capture integration €45k To Varian, a Siemens Healthineers company · per new customer DLCExpert API access & joint integration €14k To Mirada Medical · per new customer Limbus Contour API access & integration €11k To Limbus AI · per new customer Open-source DICOM toolkit support & maintenance €1.8k To dcm4che open-source community · fixed monthly Core metric & control-chart engine €220k one-off One-off build cost Pre-edit contour capture & integration layer €230k one-off One-off build cost Regulatory classification, QMS & NHS compliance pack €165k one-off One-off build cost Observer-variability calibration methodology €90k one-off One-off build cost Reference-trust pilot & validation publication €132k one-off One-off build cost SaaS hosting & dashboard operations €92k Running cost, scales with customers Customer success & physics support €110k Running cost, scales with customers Vendor telemetry & PMS report production €280k Running cost, scales with customers Sales & physics-community presence €79k Running cost, scales with customers Independent contour review audits €54k Running cost, scales with customers Revenue Streams€872k in year 3 Core QA Dashboard subscription — NHS radiotherapy departments €190k NHS radiotherapy physics teams pays · recurring Observer-variability calibration onboarding study — NHS departments €205k NHS radiotherapy physics teams pays · one time Core QA Dashboard subscription — US academic cancer centres €475k US academic cancer centres pays · recurring Fleet telemetry & PMS report subscription — auto-contouring vendors €2.8k Auto-contouring vendors pays · recurring Regulatory pathway and liability allocationidea-specific 4 Whether ContourDrift is classified as a medical device under MDR/FDA swings time-to-market by 12-24 months, and liability allocation determines whether clinics and vendors embrace or resist the telemetry.
Device classification Determine early whether it is a Class IIa accessory (informs clinical use of auto-contouring) or non-device QA/quality-management software; get a notified-body or legal opinion before building the QMS. FDA route Decide between 510(k) as an accessory to cleared auto-contouring software or enforcement-discretion QA tool; run a pre-submission meeting before US entry. Liability and vendor notification duties Contracts must define who acts on drift alerts, whether findings trigger vigilance reporting, and how vendor failures are disclosed — vendors will resist telemetry that exposes their production performance. PMS as product-market fit Design the monthly export to map directly onto MDR Articles 83-86 and FDA post-market surveillance expectations so compliance documentation becomes the reason to buy, not just a feature. Vendor API access and data acquisitionidea-specific 4 The entire value stream depends on capturing the raw pre-edit AI contour; if OEMs block access, a vendor-independent capture path is the difference between a business and a dead idea.
API audit across contouring ecosystem Audit Varian/Eclipse, Mirada, Limbus, RaySearch and others for whether pre-edit AI contours are stored and exposed via API or as DICOM-RT objects. PACS/middleware fallback Build a capture path at the department's own DICOM-RT structure-set level (contour versioning) so the product works without OEM cooperation. Partnership vs neutral positioning Choose between embedding with one vendor (e.g. Limbus or Mirada for co-marketing and guaranteed data access) and staying vendor-neutral to aggregate fleet telemetry across all tools. Data governance GDPR/DPA-compliant processing, per-trust DPIAs, and a de-identification pipeline before any contour data leaves the clinic for vendor telemetry. Clinical validation and physics-team trustidea-specific 4 Physics teams buy evidence, not dashboards; the alerting logic must demonstrably catch real drift with acceptable false-alarm rates given high inter-observer variability in manual contouring.
Retrospective multi-site validation Replay thousands of archived auto-plus-approved contour pairs to show the control charts detect known scanner, protocol or population changes with quantified sensitivity and false-alarm rate. Observer-variability calibration Build per-structure local variability datasets using multi-observer methodology so control limits are set beyond human noise; publish the calibration method. Automation-bias sentinel validation Validate the rising unedited-fraction signal against graded retrospective review of accepted-unmodified cases, mirroring the published human-factors study design. Publication strategy Target Med Phys, Radiotherapy & Oncology and AAPM/ESTRO abstracts; peer-reviewed evidence is the primary sales channel into conservative physics departments. Payers & regulators4 Actors outside the deal who decide whether it can happen or who pays.
NHS England National commissioner; radiotherapy service specifications and network-level procurement could fund multi-trust rollout, though individual trusts otherwise pay from local physics budgets. BSI Group Notified body gating the EU/UK market if ContourDrift is classified as a medical device; audits the ISO 13485 QMS and technical file for UKCA/CE marking. MHRA UK regulator whose software classification guidance determines the UKCA route and post-market surveillance expectations for the beachhead market. FDA (CDRH) US regulator for the expansion market; 510(k)/De Novo pathway if classified as a device, with enforcement discretion possible for QA/audit software.