Dynamic stress relaxation of orthodontic thermoplastic materials in a simulated oral environment
Dongyu Fang, Ning Zhang, Hui Chen, Yuxing Bai · 2013 · 120 citationsRead the paper
Mechanical properties are crucial for screening orthodontic thermoplastic materials for invisible aligners. However, most of previous studies were carried out within laboratory conditions which limit our understanding of the mechanical behaviors of aligners within oral environment. In this study, we studied the dynamic stress relaxation of thermoplastic materials by combination of Bose ElectroForce and a homemade temperature-controlled water bath. The 3-h stress relaxation curves of five orthodontic thermoplastic materials were measured within 37°C water bath as well as comparatively in ambient atmospheric environment (~20°C). The percentage residual stress at 0, 30, 60, 90, 120, 150, and 180 min was selected for statistical analyses. As expected, the experimental results showed that the residual stress within all five materials decreased with time, and that this process was significantly accelerated in the 37°C water bath (p<0.05). Compared with other materials, Erkodur and Masel exhibited slower relaxing rates in the 37°C water bath (p<0.05).
What the full text shows
Shown in the lab- Hygrothermal aging (37°C water bath) significantly accelerates stress relaxation compared to ambient atmospheric environment (~20°C). — Residual forces dropped to 42.29–66.56% of initial forces after 3 hours in 37°C water (Five commercial orthodontic thermoplastic materials at 5% strain)
- Erkodur and Masel exhibit slower stress relaxation rates in a simulated oral environment than other tested materials. — p < 0.05 (37°C water bath)
- In ambient atmospheric environment, Erkodur shows the slowest relaxation rate. — Residual stress significantly higher than Duran (90–180 min) and Keystone (120–180 min) (Ambient atmospheric environment (~20°C))
- Setup
- Five commercial thermoplastic materials; dumbbell-shaped specimens (ISO 527-3 type 5); 37°C water bath vs. ~20°C ambient air.
- How
- The researchers used a Bose ElectroForce ELF 3100 combined with a custom-built temperature-controlled water bath and glass chamber to measure dynamic stress relaxation. Dumbbell-shaped specimens were subjected to 5% strain and monitored for 180 minutes.
- Limitations
- Short testing duration (3 hours) · Relatively small deformation (5% strain) · Lack of chemical complexity (distilled water used instead of artificial saliva) · Does not account for periodic removal and reinsertion of aligners
Summarized by Gemma 4 from the open-access full text · 29 Oct 2026. Read it