A mobile sensor network to map carbon dioxide emissions in urban environments
Joseph K. Lee, Andreas Christen, Rick Ketler, Zoran Nesic · 2017 · 46 citationsRead the paper
Abstract. A method for directly measuring carbon dioxide (CO2) emissions using a mobile sensor network in cities at fine spatial resolution was developed and tested. First, a compact, mobile system was built using an infrared gas analyzer combined with open-source hardware to control, georeference, and log measurements of CO2 mixing ratios on vehicles (car, bicycles). Second, two measurement campaigns, one in summer and one in winter (heating season) were carried out. Five mobile sensors were deployed within a 1 × 12. 7 km transect across the city of Vancouver, BC, Canada. The sensors were operated for 3.5 h on pre-defined routes to map CO2 mixing ratios at street level, which were then averaged to 100 × 100 m grid cells. The averaged CO2 mixing ratios of all grids in the study area were 417.9 ppm in summer and 442.5 ppm in winter. In both campaigns, mixing ratios were highest in the grid cells of the downtown core and along arterial roads and lowest in parks and well vegetated residential areas. Third, an aerodynamic resistance approach to calculating emissions was used to derive CO2 emissions from the gridded CO2 mixing ratio measurements in conjunction with mixing ratios and fluxes collected from a 28 m tall eddy-covariance tower located within the study area. These measured emissions showed a range of −12 to 226 CO2 ha−1 h−1 in summer and of −14 to 163 kg CO2 ha−1 h−1 in winter, with an average of 35.1 kg CO2 ha−1 h−1 (summer) and 25.9 kg CO2 ha−1 h−1 (winter). Fourth, an independent emissions inventory was developed for the study area using buildings energy simulations from a previous study and routinely available traffic counts. The emissions inventory for the same area averaged to 22.06 kg CO2 ha−1 h−1 (summer) and 28.76 kg CO2 ha−1 h−1 (winter) and was used to compare against the measured emissions from the mobile sensor network. The comparison on a grid-by-grid basis showed linearity between CO2 mixing ratios and the emissions inventory (R2 = 0. 53 in summer and R2 = 0. 47 in winter). Also, 87 % (summer) and 94 % (winter) of measured grid cells show a difference within ±1 order of magnitude, and 49 % (summer) and 69 % (winter) show an error of less than a factor 2. Although associated with considerable errors at the individual grid cell level, the study demonstrates a promising method of using a network of mobile sensors and an aerodynamic resistance approach to rapidly map greenhouse gases at high spatial resolution across cities. The method could be improved by longer measurements and a refined calculation of the aerodynamic resistance.
What the full text shows
Working prototype- Measured CO2 emissions ranged from -12 to 226 kg CO2 ha−1 h−1 in summer and -14 to 163 kg CO2 ha−1 h−1 in winter. — Average 35.1 kg CO2 ha−1 h−1 (summer) and 25.9 kg CO2 ha−1 h−1 (winter) (100 x 100 m grid cells in Vancouver, BC)
- Linearity observed between mobile CO2 mixing ratios and independent emissions inventories. — R2 = 0.53 (summer) and R2 = 0.47 (winter) (Grid-by-grid comparison)
- Measured grid cells showed agreement with emissions inventory within a factor of 2. — 49% (summer) and 69% (winter) of cells (Grid-by-grid comparison)
- Mobile sensors successfully detected negative net ecosystem exchange (net CO2 uptake). — -12 kg CO2 ha−1 h−1 (Forest area (Stanley Park))
- Average CO2 mixing ratios across the study area were higher in winter. — 417.9 ppm (summer) vs 442.5 ppm (winter) (100 x 100 m grid cells)
- Setup
- 5 mobile sensors deployed on cars and bicycles across a 1 x 12.7 km transect in Vancouver, BC, for 3.5 hours per campaign (summer and winter).
- How
- Developed a 'DIYSCO2' mobile system using a Li-820 infrared gas analyzer, Arduino microcontroller, and GPS. Combined mobile mixing ratio data with an aerodynamic resistance approach and data from a 28m eddy-covariance tower to derive emissions.
- Limitations
- Large errors (up to an order of magnitude) observed at the individual grid cell level. · Building emissions are less clearly correlated with mixing ratios than traffic emissions due to roof-level venting. · High sensor density required for full city coverage (estimated 230 sensors for Vancouver).
Summarized by Gemma 4 from the open-access full text · 8 Oct 2026. Read it