The modified pancreatic stent system for prevention of post-ERCP pancreatitis: a case-control study
Cheng Zhang, Yulong Yang, Yuefeng Ma, Hongwei Zhang, Jingyi Li, Mei‐Ju Lin et al. · 2017 · 16 citationsRead the paper
All 8 authors
BACKGROUND: Prophylactic pancreatic stents after endoscopic retrograde cholangiopancreatography (ERCP) can help prevent post-ERCP pancreatitis. However most of the pancreatic stents need to be removed by another ERCP. The aim of this observational study was to investigate the feasibility and effectiveness of the modified pancreatic stent system for prevention of post-ERCP pancreatitis. METHODS: From November 2013 to November 2015, a total of 230 patients who had prophylactic pancreatic stent placed for prevention of post-ERCP pancreatitis at a single institution were identified and stratified. In this case-control design, 150 patients received an ordinary pancreatic stent, and 80 patients received the modified pancreatic stent. The main outcome measures were the difficulty level and complications of pancreatic stent placement and extraction between the two groups. RESULTS: In ordinary group, the average time of pancreatic stent and nasal biliary drainage placement was 3.5 ± 0.6 min. There were 13 cases of stent proximal migration (8.7%), 20 cases of stent spontaneous abscission (13.3%), 5 cases of acute pancreatitis (3.3%) (2 cases for stent abscission) and 7 cases of hyperamylasemia (4.7%) after ERCP. One hundred thirty patients received extra duodenoscope (86.7%) to remove the stent, and 4 cases had acute pancreatitis and 5 patients had hyperamylasemia after removing the proximal migratory stents. In modified group, the average time of pancreatic stent system placement was 4.9 ± 0.7 min, but there was only one case of stent abscission (1.3%), 2 cases of acute pancreatitis (2.5%) and 3 cases of hyperamylasemia (3.8%). The new pancreatic stents were removed directly under x-ray without complication. CONCLUSIONS: The modified pancreatic stent system has the same effect of preventing post-ERCP pancreatitis, lower rate of stents proximal migration and spontaneous abscission, and the advantage of easier removed compared with ordinary pancreatic stent.
What the full text shows
Working prototype- The modified pancreatic stent system eliminated proximal migration of the stent. — 0% vs. 8.7% in ordinary group (Prophylactic pancreatic stent placement for PEP prevention)
- The modified system significantly reduced the rate of spontaneous stent abscission. — 1.3% vs. 13.3% in ordinary group (Prophylactic pancreatic stent placement for PEP prevention)
- The modified system allowed for removal directly under X-ray without complications, whereas the ordinary group required additional endoscopy for most removals. — 86.7% of ordinary group required extra duodenoscope for removal (Stent extraction phase)
- The modified system showed no significant difference in preventing acute pancreatitis compared to ordinary stents. — 2.5% vs. 3.3% (P > 0.05) (Post-ERCP period)
- The modified system showed no significant difference in hyperamylasemia rates compared to ordinary stents. — 3.8% vs. 4.7% (P > 0.05) (Post-ERCP period)
- Placement time for the modified system was longer than for the ordinary system. — 4.9 ± 0.7 min vs. 3.5 ± 0.6 min (P < 0.05) (Intraoperative placement)
- Setup
- 230 patients (150 ordinary group, 80 modified group) treated at a single institution between November 2013 and November 2015.
- How
- A retrospective case-control study comparing a modified pancreatic stent system (connected to a nasobiliary catheter by a line) against ordinary pancreatic stents. Outcomes were measured via review of electronic medical records, including X-ray, laboratory results, and endoscopic reports.
- Limitations
- Retrospective study design · Small sample size · Single-center study performed by a single endoscopist
Summarized by Gemma 4 from the open-access full text · 2 Nov 2026. Read it