Direct detection of sub-GeV dark matter using a superfluid He4 target

S. A. Hertel, A. Biekert, J. Lin, V. Senthil Velan, Daniel N. McKinsey · 2019 · 137 citationsRead the paper

A promising technology concept for sub-GeV dark matter detection is described, in which low-temperature microcalorimeters serve as the sensors and superfluid $^{4}\mathrm{He}$ serves as the target material. We name this concept ``HeRALD,'' helium roton apparatus for light dark matter. A superfluid helium target has several advantageous properties, including a light nuclear mass for better kinematic matching with light dark matter particles, copious production of scintillation light, extreme intrinsic radiopurity, high impedance to external vibration noise, and a unique ``quantum evaporation'' signal channel enabling the detection of phononlike modes via liberation of $^{4}\mathrm{He}$ atoms into a vacuum. In this concept, both scintillation photons and triplet excimers are detected using calorimeters, including calorimeters immersed in the superfluid. Kinetic excitations of the superfluid medium (rotons and phonons) are detected using quantum evaporation and subsequent atomic adsorption onto a calorimeter suspended in vacuum above the target helium. The energy of adsorption amplifies the phonon/roton signal before calorimetric sensing, producing a gain mechanism that can reduce the technology's recoil energy threshold below the calorimeter energy threshold. We describe signal production and signal sensing probabilities, and estimate the resulting electron recoil discrimination. We simulate radioactive backgrounds from gamma rays and construct an overall background spectrum expectation also including neutrons and solar neutrinos. Finally, we calculate projected sensitivities to dark matter--nucleon elastic scattering, demonstrating that even very small (sub-kg) target masses can probe wide regions of as-yet untested dark matter parameter space.

What the full text shows

Theory or simulation
  • Estimated electron recoil leakage fraction at 50% nuclear recoil acceptance. — ~10^-6 at 1 keV (Using quasiparticle vs atomic excitation ratio as discriminator)
  • Calculated recoil energy threshold for a 'shovel ready' detector configuration. — 39 eV (Based on 3.5 eV calorimeter resolution, 5% evaporation efficiency, and 9x adsorption gain)
  • Projected sensitivity for a first-generation experiment. — 10 g target mass, 100 days runtime (Threshold of 40 eV)
  • Projected sensitivity for future generations. — 1 meV threshold, 100 kg target mass, 1 year runtime (Theoretical limit)
  • Defined neutrino floor for helium-target detectors. — 1.6 tonne-yr exposure (Based on 1000 expected CEvNS events)
Setup
Simulation-based study of a detector consisting of a superfluid 4He target with immersed calorimeters and a suspended vacuum calorimeter.
How
The authors proposed a detector concept (HeRALD) using superfluid 4He and microcalorimeters to detect scintillation photons, triplet excimers, and quasiparticles via quantum evaporation. They performed simulations of signal partitioning (Lindhard model), background spectra (gamma, neutron, solar neutrinos), and projected sensitivity using a Profile Likelihood Ratio (PLR) analysis.
Limitations
Requires prevention of helium film flow to the suspended calorimeter to maintain adsorption gain. · Dependence on extrapolation of ionization and excitation cross sections below 100 eV. · Sensitivity below 19.77 eV is heavily dependent on quantum evaporation efficiency.