Validation of automated sepsis surveillance based on the Sepsis-3 clinical criteria against physician record review in a general hospital population: observational study using electronic health records data
John Karlsson Valik, Logan Ward, Hideyuki Tanushi, Kajsa Müllersdorf, Anders Ternhag, Ewa Aufwerber et al. · 2020 · 64 citationsRead the paper
All 14 authors
Anna Färnert, Anders F. Johansson, Mads Lause Mogensen, Brian W. Pickering, Hercules Dalianis, Aron Henriksson, Vitaly Herasevich, Pontus Nauclér
Background Surveillance of sepsis incidence is important for directing resources and evaluating quality-of-care interventions. The aim was to develop and validate a fully-automated Sepsis-3 based surveillance system in non-intensive care wards using electronic health record (EHR) data, and demonstrate utility by determining the burden of hospital-onset sepsis and variations between wards. Methods A rule-based algorithm was developed using EHR data from a cohort of all adult patients admitted at an academic centre between July 2012 and December 2013. Time in intensive care units was censored. To validate algorithm performance, a stratified random sample of 1000 hospital admissions (674 with and 326 without suspected infection) was classified according to the Sepsis-3 clinical criteria (suspected infection defined as having any culture taken and at least two doses of antimicrobials administered, and an increase in Sequential Organ Failure Assessment (SOFA) score by >2 points) and the likelihood of infection by physician medical record review. Results In total 82 653 hospital admissions were included. The Sepsis-3 clinical criteria determined by physician review were met in 343 of 1000 episodes. Among them, 313 (91%) had possible, probable or definite infection. Based on this reference, the algorithm achieved sensitivity 0.887 (95% CI: 0.799 to 0.964), specificity 0.985 (95% CI: 0.978 to 0.991), positive predictive value 0.881 (95% CI: 0.833 to 0.926) and negative predictive value 0.986 (95% CI: 0.973 to 0.996). When applied to the total cohort taking into account the sampling proportions of those with and without suspected infection, the algorithm identified 8599 (10.4%) sepsis episodes. The burden of hospital-onset sepsis (>48 hour after admission) and related in-hospital mortality varied between wards. Conclusions A fully-automated Sepsis-3 based surveillance algorithm using EHR data performed well compared with physician medical record review in non-intensive care wards, and exposed variations in hospital-onset sepsis incidence between wards.
What the full text shows
Working prototype- The automated Sepsis-3 algorithm demonstrated high diagnostic accuracy compared to physician review. — sensitivity 0.887, specificity 0.985, PPV 0.881, NPV 0.986 (Extrapolated to the entire hospital cohort of non-ICU wards)
- The algorithm identified a significant proportion of sepsis episodes in the total cohort. — 8599 episodes (10.4% of all admissions) (Total cohort of 82,653 hospital admissions)
- The algorithm showed lower sensitivity for hospital-onset (HO) sepsis compared to community-onset (CO) sepsis. — HO sensitivity 0.794 vs CO sensitivity 0.910 (Non-ICU wards)
- ICD-10 codes significantly underestimate sepsis incidence compared to the clinical algorithm. — only 13.4% of sepsis patients had an ICD-code indicating sepsis (Total cohort)
- Physician review confirmed that the majority of Sepsis-3 criteria cases were true infections. — 91% had possible, probable or definite infection (Validation sample of 343 episodes meeting Sepsis-3 criteria)
- Setup
- 82,653 hospital admissions from an academic center (July 2012 - December 2013), excluding obstetric and pediatric wards and censoring ICU time.
- How
- A rule-based algorithm was developed using EHR data to identify suspected infection (cultures + antimicrobials) and organ dysfunction (SOFA score increase >2). Performance was validated against a stratified random sample of 1,000 admissions reviewed by two infectious disease physicians.
- Limitations
- Missing SOFA score data led to assumptions of 'normal' values, potentially affecting classification. · Lower sensitivity for hospital-onset sepsis due to organ dysfunction being recorded only in free text. · Single-center study requiring validation across different EHR systems. · Algorithm not yet implemented or evaluated in a real-time clinical scenario.
Summarized by Gemma 4 from the open-access full text · 28 Oct 2026. Read it