CMF-Net: craniomaxillofacial landmark localization on CBCT images using geometric constraint and transformer
Gang Lu, Huazhong Shu, Han Bao, Youyong Kong, Chen Zhang, Bin Yan et al. · 2023 · 20 citationsRead the paper
All 8 authors
Yuanxiu Zhang, Jean-Louis Coatrieux
Accurate and robust anatomical landmark localization is a mandatory and crucial step in deformation diagnosis and treatment planning for patients with craniomaxillofacial (CMF) malformations. In this paper, we propose a trainable end-to-end cephalometric landmark localization framework on Cone-beam computed tomography (CBCT) scans, referred to as CMF-Net, which combines the appearance with transformers, geometric constraint, and adaptive wing (AWing) loss. More precisely: (1) we decompose the localization task into two branches: the appearance branch integrates transformers for identifying the exact positions of candidates, while the geometric constraint branch at low resolution allows the implicit spatial relationships to be effectively learned on the reduced training data. (2) We use the AWing loss to leverage the difference between the pixel values of the target heatmaps and the automatic prediction heatmaps. We verify our CMF-Net by identifying the 24 most relevant clinical landmarks on 150 dental CBCT scans with complicated scenarios collected from real-world clinics. Comprehensive experiments show that it performs better than the state-of-the-art deep learning methods, with an average localization error of 1.108 mm (the clinically acceptable precision range being 1.5 mm) and a correct landmark detection rate equal to 79.28%. Our CMF-Net is time-efficient and able to locate skull landmarks with high accuracy and significant robustness. This approach could be applied in 3D cephalometric measurement, analysis, and surgical planning.
What the full text shows
Working prototype- CMF-Net achieved an average localization error (MRE) across test sets. — 1.108 mm (24 clinical landmarks on 150 dental CBCT scans)
- Successful detection rate (SDR) within the clinically acceptable precision range. — 79.28% at 1.5 mm (Across all test sets)
- CMF-Net+Refinement achieved the lowest MRE and highest SDR without missing landmarks. — 0.938 mm MRE (Across all test sets)
- Adding geometric constraints (GC) to the baseline model significantly reduced localization error. — >0.5 mm lower MRE and >15% higher SDR (Ablation study on Test1 data)
- Setup
- 150 dental CBCT scans (ages 7-41) from the Affiliated Hospital of Stomatology, Nanjing Medical University, split into training (50%), Test1 (33%), and Test2 (17%).
- How
- The authors developed CMF-Net, a dual-branch framework combining an appearance branch with transformers for global context and a geometric constraint branch for spatial relationships. It utilizes an adaptive wing (AWing) loss for heatmap regression and a quadratic curve fitting method for sub-pixel coordinate decoding.
- Limitations
- High localization errors persist for landmarks located on the mandible. · Performance decreases in the presence of severe aliasing artifacts from metallic implants.
Summarized by Gemma 4 from the open-access full text · 8 Oct 2026. Read it