Seedlabs
Source research

Mechanical deterioration of passive self-ligating lingual brackets under simulated prolonged use: An in vitro study

Prasad Nalabothu, Konstantina Papadopoulou, Michel Dalstra, Giuseppe Scuzzo, Carlalberta Verna · 2025 · 0 citationsRead the paper

<h2>ABSTRACT</h2><h3>Background</h3> Passive, self-ligating lingual brackets are favored in Orthodontics for their simplified mechanism, eliminating the need for elastomeric and metallic ligatures. However, limited data exists on the effects of repeated use on their mechanical durability. An understanding of these effects is essential to ensure their long-term clinical performance. This study evaluates the mechanical degradation of the sliding cap locking mechanism of passive self-ligating lingual brackets after repeated opening and closing cycles. <h3>Methods</h3> In this in vitro study, 60 ALIAS mandibular incisor brackets were subjected to repeated opening and closing cycles (5, 10, 20, and 40 cycles). Mechanical tests were performed using an Instron 3344 electronic universal testing machine to measure maximum force at failure (<i>F</i><sub>max</sub>), energy absorption at <i>F</i><sub>max</sub> (<i>U</i><sub>max</sub>), and initial stiffness of the bracket opening mechanism (<i>K</i>). <h3>Results</h3> The sliding cap remained functional throughout the test period. However, a significant reduction in <i>F</i><sub>max</sub>, <i>U</i><sub>max,</sub> and <i>K</i> over multiple opening and closing cycles. <i>F</i><sub>max</sub> showed a significant reduction after 5 opening and closing cycles (<i>P</i> = 0.0069), <i>U</i><sub>max</sub> after 10 cycles (<i>P</i> = 0.0243), and <i>K</i> showed after 5 cycles (<i>P</i> = 0.0002). The <i>F</i><sub>max</sub> reached a plateau at about 8–10 Newtons after 10 cycles, <i>U</i><sub>max</sub> at about 2.0 mJ (millijoules), and <i>K</i> at 50 N/mm after 10 cycles. <h3>Conclusions</h3> The study highlights significant advantages of passive self-ligating lingual brackets, showcasing their excellent initial performance. While ALIAS brackets may experience minor mechanical deterioration of the properties, their overall performance remains strong enough for entire duration of orthodontic treatment (2–3 years).

What the full text shows

Shown in the lab
  • Maximum force at failure (Fmax) significantly reduced after 5 cycles and reached a plateau after 10 cycles. — 8–10 N plateau vs. 12.66 N baseline (ALIAS mandibular incisor brackets)
  • Initial stiffness (K) significantly declined after 5 cycles and stabilized after 10 cycles. — 50 N/mm plateau vs. 57.35 N/mm baseline (ALIAS mandibular incisor brackets)
  • Energy absorption at Fmax (Umax) decreased after 5 cycles. — 25.85% reduction after 5 cycles (ALIAS mandibular incisor brackets)
  • The sliding cap mechanism maintained structural integrity without fractures or permanent deformations. (Up to 40 opening and closing cycles)
Setup
60 ALIAS mandibular incisor brackets (0.018-inch slot) laser-welded to screw heads; tested with 0.016 x 0.016-inch stainless steel wire.
How
60 brackets were subjected to 5, 10, 20, and 40 opening/closing cycles. Mechanical properties (Fmax, Umax, K) were measured using an Instron 3344 electronic universal testing machine.
Limitations
In vitro study simulating use rather than in vivo clinical testing. · Limited to a single bracket brand (ALIAS).

Summarized by Gemma 4 from the open-access full text · 9 Oct 2026. Read it