Seedlabs
Source research

Multiscale detection of power quality disturbances and cyber intrusions in smart grids using NSCT and frequency band scalograms

Pampa Sinha, Kaushik Paul, Snehalika Snehalika, Idamkati Kasireddy, Ardhala Bala Krishna, D S Naga Malleswara Rao et al. · 2025 · 21 citationsRead the paper

All 8 authors

Hassan Abdurrahman Shuaibu, Taha Selim Ustun

This paper presents a novel multiscale signal processing framework for power quality disturbance (PQD) and cyber intrusion detection in smart grids, combining Non-Subsampled Contourlet Transform (NSCT), Split Augmented Lagrangian Shrinkage Algorithm (SALSA), and Morphological Component Analysis (MCA). A key innovation lies in an adaptive weighting mechanism within NSCT's directional sub bands, enabling dynamic energy redistribution and enhanced representation of both low-frequency anomalies (e.g., voltage sags/swells) and high-frequency distortions (e.g., harmonics, transients). SALSA-based sparse optimization achieves an average signal-to-noise ratio (SNR) improvement of 12.8 dB, preserving essential transient structures, while MCA isolates fault-relevant morphological components for better interpretability. Extensive simulations on both synthetic signals and the IEEE 14-bus test system demonstrate detection accuracies of 98.6% for PQDs and 97.2% for cyber intrusions, including False Data Injection (FDI), Denial of Service (DoS), and Command Injection attacks. Each intrusion exhibits unique time-frequency scalogram signatures, which are effectively visualized using high-resolution, denoised 2D/3D spectrograms generated via adaptive Q-Factor Wavelet Transform (AQWT) and Short-Time Fourier Transform (STFT). Compared to baseline methods like STFT-only and DWT-SVM pipelines, the proposed NSCT-SALSA-MCA framework improves detection precision by 14-18%, reduces false positives by 22%, and remains robust under 30 dB noise and 20% data loss. Incorporating AI-driven anomaly detection and resilient state estimation further enables early flagging of compromised measurements, securing applications such as Economic Dispatch and Optimal Power Flow (OPF). The resulting scalograms provide interpretable visual insights, marking a significant advancement in smart grid monitoring with potential for real-time deployment at the edge.

What the full text shows

Shown in the lab
  • Detection accuracy for power quality disturbances (PQDs) and cyber intrusions. — 98.6% for PQDs and 97.2% for cyber intrusions (Simulations on synthetic signals and IEEE 14-bus test system)
  • Improvement in detection precision and reduction in false positives compared to STFT-only and DWT-SVM pipelines. — 14-18% higher precision; 22% fewer false positives (Compared to baseline methods)
  • Average signal-to-noise ratio (SNR) improvement via SALSA-based sparse optimization. — 12.8 dB (Denoising NSCT sub-bands)
  • Robustness of the framework under noise and data loss. — Robust under 30 dB noise and 20% data loss (Detection of PQDs and cyber intrusions)
  • Energy retention of the signal post-NSCT application. — 9.7% to 20.2% energy reduction (Across different scales and directions)
Setup
Simulations using synthetic signals and the IEEE 14-bus test system.
How
The framework combines Non-Subsampled Contourlet Transform (NSCT) with adaptive weighting, SALSA for sparse denoising, and Morphological Component Analysis (MCA) for feature isolation. It utilizes AQWT and STFT for time-frequency visualization and MSVM for final disturbance classification.
Limitations
High computational power and domain expertise required for implementation · Performance in highly dynamic or atypical grid conditions may require further parameter tuning · Reliance on diverse and representative datasets for machine learning components · Potential for new types of disturbances to emerge that are not covered by the current model

Summarized by Gemma 4 from the open-access full text · 1 Nov 2026. Read it