Direct Energy Conversion for a D–³He Tandem-Mirror Burner: Recovering Charged-Particle Power Directly Without a Thermal Cycle
Priyanca Ford, G L Kulcinski · 2026 · 115 citationsRead the paper
A deuterium–helium-3 (D–³He) tandem-mirror burner puts most of its fusion power into charged particles, so it admits an option a tokamak does not: recover the exhaust electrostatically, as electricity, without a thermal cycle or a turbine on the direct channel. This paper is the flagship, review-length treatment of that option for the Kronos burner (engineering gain Q_E=1.318 at P_fus=4298.5 MW, neutron fraction f_n=5.44 %, plug potential e_i=248.75 keV, on the open field lines downstream of a 26.49 T plug coil that is a distinct magnet from the breeder's 16.84 T centrepost). We write the governing physics as explicit, step-by-step derivations: the D–³He energetics and the Bosch–Hale reactivity that fix the operating point; the Pastukhov ambipolar confinement that sets the axial end-loss channel; the synchrotron-transport calculation that pins the electron temperature; the Stix collisional slowing-down partition, which shows that at a reactor electron temperature T_e≈89.7 keV the 14.68 MeV fusion proton is born more than an order of magnitude above its critical energy and hands ≈83 % of its energy to the electrons, so that the thermalized axial exit carries an electron-dominant split (≈55.5 % electron/thermal against ≈44.5 % directed ion) that inverts the received birth-spectrum picture and holds across 20–200 keV; the multi-stage electrostatic collector and its Child–Langmuir space-charge limit; the travelling-wave converter for the proton channel; and a quasineutral two-species expander that recovers the directed electron stream against the ambipolar potential of the expansion. We resolve the direct-converter efficiency into a defensible ladder — frozen conservative anchor η_dec=0.49, floor 0.56, Moir–Barr design 0.70, ideal proton-only ceiling 0.85 — and place it correctly in the plant balance: booked at the design value the burner delivers P_out=3522.0 MWe against P_in=2672.0 MWe (+850.0 MWe net, recirculating fraction 0.759), but the net-positive knee sits at η_dec≈0.52, so conversion is a bounded upside lever, not the closure mechanism — closure is gated by the recirculating plug power, and central-cell length, not converter efficiency, buys the net margin (+104/+850/+2832 MWe at 55/440/1400 m). A 40,000-sample global uncertainty study returns Q_E=1.317±0.14 with P(Q_E>1)=1.0, and a Saltelli–Sobol decomposition identifies the plug density ratio (S_1=0.41) and central-cell β (rank correlation 0.93), not η_dec, as the leading drivers. We give the GPU-HPC methodology (the codes, not dollars), map the converter onto the two products — Aegis forward-base (grid-independent black-start in ≈42 s) and MetroVolt data-center (HVDC-native 88.1 % source-to-chip against 75.9 % for a conventional AC chain) — and benchmark against the published venetian-blind, travelling-wave, expander, and mirror-revival literature. Kronos has built no converter; every headline quantity is a frozen anchor in the de-risking registerR0. Key results (frozen anchors): e_i = 248.75 keV; out = 3522.0 MWe; in = 2672.0 MWe; Q_E = 1.317 ±0.14; Q = 18.35 MeV,. Methods & codes: OpenMC, Bosch–Hale. Live verification: 4 gate validator(s) with live-recompute cards (4 reproduced). See the Verification section and data/verification.csv. Related: Paper page · De-risking register · 3D model · Learn more about Kronos Part of the 2026 Kronos publication series; independently re-run and stamped in the Kronos de-risking register (DOI 10.5281/zenodo.22645689). All numerical values are frozen design-point anchors; see the register. Public research artifact. No proprietary, financial, or supply-chain information is included. Previous version: DOI 10.5281/zenodo.22132480. Please cite this version.